- Advanced Pulse Filling™ and Pulse Modeling - PWM technology, enabling the creation of specific laser pulse shapes for optimizing the quality, strength and physical appearance of welds;
- the Fiber Optic Delivery System enabling extremely even distribution of the energy throughout the weld spot (Flat Top Beam Profile);
- the Off-Line Feedback system for improved long term power stability.
Off-line Feedback
Kubo’s OFF-LINE feedback feature enables the system to offset automatically any lamp degradation or optical misalignment.
This important feature ensures a stable output power throughout the life of the lamp, ensuring consistent performance and long lamp life.
Technical Specifications
| Laser Model |
KUBO 20 |
KUBO 40 |
KUBO 60 |
KUBO 100 |
| Laser Medium |
Nd: YAG / 1064 nm |
| Excitation |
Xe FLASH LAMP |
| Average power (Max) |
20W @ 1ms, 20 Hz |
50W @ 1ms, 20 Hz |
80W @ 1ms, 20 Hz |
100W @ 1ms, 20 Hz |
| Energy / shot (max) |
10 J F.O. 440µm |
40 J F.O. 600µm |
60 J F.O. 800µm |
80 J F.O. 800µm |
| Peak Power (max) |
3.5kW @ 1ms, 5Hz |
4.5kW @ 1ms, 5Hz |
6.5kW @ 1ms, 5Hz |
6.5kW @ 1ms, 5Hz |
| Repetition rate |
1 - 20 Hz |
| Pulse width |
0.2 - 10 ms |
0.3 - 10 ms |
0.3 - 20 ms |
0.3 - 20 ms |
| Optical fiber |
S.I. 200 - 300 - 400 µm |
S.I. 300 - 400 - 600 µm |
S.I. 400 - 600 - 800 µm |
S.I. 400 - 600 - 800 µm |
| Cooling |
Integrated water / Air |
| Power supply |
230/110 VAC 50/60 Hz |
230 VAC 50/60 Hz |
| Operative temperature |
+ 10 to +35 °C ( 46 to 95 °F) |
| Weight |
64 |
64 |
80 |
120 |