Request Information




 
 
 

 

Telecom Band Pass Filters

Bandpass filters (BPF) are used to transmit one or more bands of wavelengths while blocking (or reflecting) adjacent wavelengths over extended ranges. Typical applications include wavelength division multiplexing/demultiplexing; channel bandsplitting;

Iridian Telecom Band Pass Filters Advantage:

Iridian's bandpass filters are designed to have a very sharp transition between the reject and pass bands while maintaining very low insertion loss and pass band ripple. Our proprietary deposition technology allows our bandpass filters to meet even the most demanding specifications.

Custom Telecom Band Pass Filters
In addition to the standard Telecom Band Pass Filters above, Iridian can custom-manufacture these filters to your specifications.

BPF Product Example No. 1: L-Band with Ultra Reflect
Part Number: Example

L-band band pass filter with ultra reflect down to 1350 nm.

Product Information:

Optical Specifications
Center Wavelength (nm) L-Band
Pass Band Level (dB) -0.3
Reflect Band Level (dB) -25
Peak Insertion Loss within Pass Band(dB) < 0.2
Pass Band Ripple (dB) < 0.25
Polarization Dependent Loss (PDL) (dB) < 0.1
Temperature Coefficient (pm/oC) 2
AR Coating (%R) < 0.1
Physical Specifications
No Physical Specifications data is currently available for this product.
Reliability
Environmental Testing Telcordia GR1221
Mechanical Durability Telcordia GR1221


BPF Product Example No. 2: 100 GHz 4 Skip 1
Part Number: Example

100 GHz 4 Skip 1 Band Pass Filter

Product Information:

Optical Specifications
Center Wavelength (nm) C-Band
Pass Band Level (dB) -0.13
Reflect Band Level (dB) -30
Peak Insertion Loss within Pass Band(dB) < 0.5
Pass Band Ripple (dB) < 0.13
Reflect Channel Isolation (dB) > 15
Polarization Dependent Loss (PDL) (dB) <0.05
Temperature Coefficient (pm/oC) 1
AR Coating (%R) < 0.1
Physical Specifications
No Physical Specifications data is currently available for this product.
Reliability
Environmental Testing Telcordia GR1221
Mechanical Durability Telcordia GR1221


BPF Product Example No. 3: C-Band with Ultra Reflect
Part Number: Example

Product Information:

Optical Specifications
Center Wavelength (nm) 1576
Pass Band Width
Bandwidth (nm) @ Level (dB)
90 -1
Reflect Band
WL Range (nm) @ Level (dB)
1640-1650 -45
1260-1511 -45
Reflect Band Level (dB) -45
Polarization Dependent Loss (PDL) (dB) < 0.1
Angle of Incidence (degrees) 1.8
AR Coating (%R) none (epoxy matched)
Physical Specifications
No Physical Specifications data is currently available for this product.
Reliability
Environmental Testing Telcordia GR1221
Mechanical Durability Telcordia GR1221


BPF Product Example No. 4: L-Band
Part Number: Example

Product Information:

Optical Specifications
Center Wavelength (nm) 1589
Pass Band Width
Bandwidth (nm) @ Level (dB)
> 52 -0.5
Reflect Band
WL Range (nm) @ Level (dB)
< 67 -30
Reflect Band Level (dB) -30
Peak Insertion Loss within Pass Band(dB) < 0.8
Pass Band Ripple (dB) < 0.3
Polarization Dependent Loss (PDL) (dB) < 0.05
Temperature Coefficient (pm/oC) 3
AR Coating (%R) < 0.1
Physical Specifications
No Physical Specifications data is currently available for this product.
Reliability
Environmental Testing Telcordia GR1221
Mechanical Durability Telcordia GR1221

 

 

 

 

 

Coffee Break

 
 